{"id":6870,"date":"2020-10-21T09:09:37","date_gmt":"2020-10-21T07:09:37","guid":{"rendered":"https:\/\/www.glm-laser.com\/glm\/?page_id=6870"},"modified":"2020-10-21T11:12:58","modified_gmt":"2020-10-21T09:12:58","slug":"setting-out-adapter","status":"publish","type":"page","link":"https:\/\/www.glm-laser.com\/glm\/optical-survey-instruments\/accessory\/setting-out-adapter\/","title":{"rendered":"Setting out adapter"},"content":{"rendered":"<h1 class=\"wp-block-heading\">Setting out adapter <\/h1>\n<div class=\"wp-block-image\">\n<figure class=\"alignright is-resized\"><a href=\"https:\/\/www.glm-laser.com\/glm\/wp-content\/uploads\/Absteck_Titan-Kopie-300x243.jpg\" class=\"gallery_colorbox\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.glm-laser.com\/glm\/wp-content\/uploads\/Absteck_Titan-Kopie-300x243.jpg\"  alt=\"Absteckadapter zum Anrei\u00dfen f\u00fcr Tachymeter\" width=\"165\" height=\"133\"\/><\/a><\/figure>\n<\/div>\n<p>GLM presents two completely new target centre adapters for setting out coordinates in the sub-millimetre range. With GLM&#8217;s 3D measuring systems, results in the 1\/10 mm range can be expected. But how do you get these high accuracies into reality, for example when setting out a machine layout?<\/p>\n<p>Without suitable setting out adapters you would lose a high level of accuracy. Our &#8220; setting-out_adapter_Titan&#8220; is perfectly suitable for setting out points on the ground or even on objects. Due to the strong magnetic clamp, which holds the TBR or SMR, you can even work overhead. After the exact position has been found, the user can now easily mark or outline.<\/p>\n<div class=\"wp-block-image\">\n<figure class=\"alignright\"><a href=\"https:\/\/www.glm-laser.com\/glm\/wp-content\/uploads\/absteckadapter-koerner.jpg\" class=\"gallery_colorbox\"><img decoding=\"async\" src=\"https:\/\/www.glm-laser.com\/glm\/wp-content\/uploads\/absteckadapter-koerner.jpg\"  alt=\"absteckadapter-koerner\"\/><\/a><\/figure>\n<\/div>\n<div class=\"wp-block-image\">\n<figure class=\"alignleft is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.glm-laser.com\/glm\/wp-content\/uploads\/absteckadapter-koerner-2.jpg\" alt=\"absteckadapter-koerner-2\" width=\"137\" height=\"103\"\/><\/figure>\n<\/div>\n<p>Another new development is the &#8220; setting out adapter_punch&#8220;. This adapter is particularly suitable for setting out ground points. If the coordinate is reached by moving the adapter, a small impact with a hammer is sufficient. The hardened centre punch leaves a precise marking. Points cannot be determined faster than with this tool!<\/p>\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<p> Do you need further accessories? Then take a look at our extensive selection by\u00a0<a href=\"https:\/\/www.glm-laser.com\/glm\/optical-survey-instruments\/accessory\/\/?lang=en\"><strong>clicking here<\/strong><\/a> <\/p>\n<div class=\"wp-block-image\">\n<figure class=\"alignleft\"><img decoding=\"async\" src=\"https:\/\/www.glm-laser.com\/glm\/wp-content\/uploads\/pdf-icon.png\" alt=\"Download PDF\"\/><\/figure>\n<\/div>\n<div class=\"wp-block-file\"><a href=\"https:\/\/www.glm-laser.com\/glm\/wp-content\/uploads\/GLM-Absteckadapter_en.pdf\">Stake-out\/ Stake-out adapter<\/a><a href=\"https:\/\/www.glm-laser.com\/glm\/wp-content\/uploads\/GLM-Absteckadapter_en.pdf\" class=\"wp-block-file__button\" download>download<\/a><\/div>\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Setting out adapter GLM presents two completely new target centre adapters for setting out coordinates in the sub-millimetre range. With GLM&#8217;s 3D measuring systems, results in the 1\/10 mm range can be expected. But how do you get these high accuracies into reality, for example when setting out a machine layout? Without suitable setting out [&hellip;]<\/p>\n","protected":false},"author":4,"featured_media":0,"parent":5005,"menu_order":7,"comment_status":"closed","ping_status":"closed","template":"page_submenu.php","meta":{"footnotes":""},"class_list":["post-6870","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.glm-laser.com\/glm\/wp-json\/wp\/v2\/pages\/6870"}],"collection":[{"href":"https:\/\/www.glm-laser.com\/glm\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.glm-laser.com\/glm\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.glm-laser.com\/glm\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.glm-laser.com\/glm\/wp-json\/wp\/v2\/comments?post=6870"}],"version-history":[{"count":15,"href":"https:\/\/www.glm-laser.com\/glm\/wp-json\/wp\/v2\/pages\/6870\/revisions"}],"predecessor-version":[{"id":6998,"href":"https:\/\/www.glm-laser.com\/glm\/wp-json\/wp\/v2\/pages\/6870\/revisions\/6998"}],"up":[{"embeddable":true,"href":"https:\/\/www.glm-laser.com\/glm\/wp-json\/wp\/v2\/pages\/5005"}],"wp:attachment":[{"href":"https:\/\/www.glm-laser.com\/glm\/wp-json\/wp\/v2\/media?parent=6870"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}