{"id":9735,"date":"2021-03-05T12:39:03","date_gmt":"2021-03-05T11:39:03","guid":{"rendered":"https:\/\/www.glm-laser.com\/glm\/?page_id=9735"},"modified":"2021-03-05T12:39:05","modified_gmt":"2021-03-05T11:39:05","slug":"sokkia-ix-1205","status":"publish","type":"page","link":"https:\/\/www.glm-laser.com\/glm\/optical-survey-instruments\/sokkia-ix-series\/sokkia-ix-1205\/","title":{"rendered":"Sokkia iX 1205"},"content":{"rendered":"<h1 class=\"wp-block-heading\">Sokkia iX 1205<\/h1>\n<p>The Sokkia iX-1205 motorized total station has been available since 2020. GLM Laserme\u00dftechnik provides an all-inclusive service (inspection, repair, sales and consulting) for the Sokkia iX-1205. <\/p>\n<div class=\"wp-block-image\">\n<figure class=\"alignright is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.glm-laser.com\/glm\/wp-content\/uploads\/Sokkia-IX-Serie-1.png\" alt=\"Dieses Bild hat ein leeres Alt-Attribut. Der Dateiname ist Sokkia-IX-Serie-1.png\" width=\"192\" height=\"201\"\/><\/figure>\n<\/div>\n<p> To control the Sokkia iX-1205 a handheld or a tablet is usually used. Of course, the total station can also be controlled via on-board software. If required by the application, the RC-PR5 unit is recommended as an accessory. <\/p>\n<h3 class=\"wp-block-heading\">An extract from the technical data:<\/h3>\n<ul class=\"wp-block-list\">\n<li>Magnification\/resolution: 30x \/ 2,5\u2033<\/li>\n<li>Rotation speed: 150\u00b0 per second<\/li>\n<li>Angle measurement accuracy: 5\u2033<\/li>\n<li>Distance measurement accuracy:\n<ul>\n<li>reflectorless: +\/- (2 + 2ppm) mm<\/li>\n<li>sticker: +\/- (2 + 2ppm) mm<\/li>\n<li>prism: +\/- (1 + 2ppm) mm<\/li>\n<\/ul>\n<\/li>\n<li>Dust and water protection: IP65<\/li>\n<\/ul>\n<h3 class=\"wp-block-heading\">Accessories:<\/h3>\n<ul class=\"wp-block-list\">\n<li>Circular level for the main unit (L08C)<\/li>\n<li> Tube compass (CP7)<\/li>\n<li> Eyepiece for telescope (EL8)\n<ul>\n<li> Magnification : 40X<\/li>\n<li> Field of view : 1\u00b0 7&#8217;30\u2033<\/li>\n<\/ul>\n<\/li>\n<li> Diagonal eyepiece (DE30)<\/li>\n<li> Solar filter (OF4)<\/li>\n<li> Interface cable DOC210<\/li>\n<li> Remote Control (RC-PR5A)Battery BDC72<\/li>\n<\/ul>\n<div class=\"wp-block-file\"><a href=\"https:\/\/www.glm-laser.com\/glm\/wp-content\/uploads\/ixseries_broch_sok-1037_revd_team_en_us_lores_3.pdf\">Brochure Sokkia iX-1200      <\/a><a href=\"https:\/\/www.glm-laser.com\/glm\/wp-content\/uploads\/ixseries_broch_sok-1037_revd_team_en_us_lores_3.pdf\" class=\"wp-block-file__button\" download>download<\/a><\/div>\n<div class=\"wp-block-file\"><a href=\"https:\/\/www.glm-laser.com\/glm\/wp-content\/uploads\/ixseries_datasheet_sok-1051_reva_ltr_en_us_lores.pdf\">Data Sheet Sokkia iX-1200    <\/a><a href=\"https:\/\/www.glm-laser.com\/glm\/wp-content\/uploads\/ixseries_datasheet_sok-1051_reva_ltr_en_us_lores.pdf\" class=\"wp-block-file__button\" download>download<\/a><\/div>\n<figure class=\"wp-block-embed-youtube wp-block-embed is-type-video is-provider-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\">\n<div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"\u30c8\u30d7\u30b3\u30f3 Total Station iX-1200 SOKKIA\" width=\"500\" height=\"281\" src=\"https:\/\/www.youtube.com\/embed\/wACZmutVRBs?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div>\n<\/figure>\n<p><!--EndFragment--><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Sokkia iX 1205 The Sokkia iX-1205 motorized total station has been available since 2020. GLM Laserme\u00dftechnik provides an all-inclusive service (inspection, repair, sales and consulting) for the Sokkia iX-1205. To control the Sokkia iX-1205 a handheld or a tablet is usually used. Of course, the total station can also be controlled via on-board software. If [&hellip;]<\/p>\n","protected":false},"author":4,"featured_media":0,"parent":4968,"menu_order":2,"comment_status":"closed","ping_status":"closed","template":"page_submenu.php","meta":{"footnotes":""},"class_list":["post-9735","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.glm-laser.com\/glm\/wp-json\/wp\/v2\/pages\/9735"}],"collection":[{"href":"https:\/\/www.glm-laser.com\/glm\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.glm-laser.com\/glm\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.glm-laser.com\/glm\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.glm-laser.com\/glm\/wp-json\/wp\/v2\/comments?post=9735"}],"version-history":[{"count":1,"href":"https:\/\/www.glm-laser.com\/glm\/wp-json\/wp\/v2\/pages\/9735\/revisions"}],"predecessor-version":[{"id":9736,"href":"https:\/\/www.glm-laser.com\/glm\/wp-json\/wp\/v2\/pages\/9735\/revisions\/9736"}],"up":[{"embeddable":true,"href":"https:\/\/www.glm-laser.com\/glm\/wp-json\/wp\/v2\/pages\/4968"}],"wp:attachment":[{"href":"https:\/\/www.glm-laser.com\/glm\/wp-json\/wp\/v2\/media?parent=9735"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}